Dataplex DPX-213 Especificaciones Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 51
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
HYDROLOGICAL SERVICES
DL3 100-08 IMP
Issue 2: 15/11/2005
Black Connector Pin B
4-20mA Sense
Black Connector Pin A
Switched +12V
RRDL-3 Logger
Black Connector Pin C
Sensor 0v
12V Battery
+
Sensor 0v
Switched +12V
4-20mA Transducer
4-20mA Sense
Black Connector Pin E
Black Connector Pin D
Red Connector Pin B
Rx Da ta
Red Connector Pin A
Tx Dat a
RRDL-3 Logger
Red Connector Pin E
Gnd
P
C
DB9
DB25
3
3
2
5
2
7
Rx D
TxD
Gnd
Connection of 4-20mA River Transducer with Internal Smart Sensor
(MO=Off & Dip Sw On)
* Pinc C not used for 2-wire systems
3.1.3 Communications
The 7 pin connector with the red marking on the logger is the communications port and is setup as
follows:-
Pin Connection Signal Name
A Tx Data (Output from logger)
B Rx Data (Input to logger)
C Carrier Detect (Input to logger)
D Not Connected
E Not Connected
F Modem Power (Not Implemented)
HGnd
Direct connection to a PC (Handshake = Xon/Xoff)
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 50 51

Comentarios a estos manuales

Sin comentarios